Extraction Condensing Steam Turbine Generator Specification | |||||
Model | Rated power KW | Inlet Steam Parameter | Exhaust Pressure MPa(a) | Speed(r/min) | |
Pressure(MPa) | Temperature°C | ||||
C1 | 1000 | 1.8-3.34 | 320-435 | 0.008 | 5600/3000 |
C3 | 1500 | 1.8-4.35 | 320-535 | 0.008 | 5600/3000 |
C4.5 | 3000 | 2.3-8.89 | 390-535 | 0.007 | 5600/3000 |
C6 | 4500 | 2.3-8.89 | 390-535 | 0.007 | 3000 |
C7.5 | 6000 | 2.3-8.89 | 390-535 | 0.007 | 3000 |
C9 | 7500 | 2.3-8.89 | 390-535 | 0.007 | 3000 |
C12 | 9000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
C15 | 12000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
C18 | 15000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
C20 | 18000 | 3.5-8.89 | 430-535 | 0.006 | 3000 |
C25 | 20000 | 3.5-8.89 | 430-535 | 0.0047 | 3000 |
C30 | 30000 | 3.5-8.89 | 430-535 | 0.0047 | 3000 |
C40 | 40000 | 8.89 | 535 | 0.0047 | 3000 |
C50 | 50000 | 8.89 | 535 | 0.0047 | 3000 |
Pre-design Reference | |||||
Condensing Steam Turbine Generator Specification | |||||
Model | Rated output KW | Inlet Steam Parameter | Exhaust Pressure MPa(a) | Rated Speed (r/min) | |
Pressure MPa(a) | Temperature°C | ||||
N1 | 1000 | 0.45-3.34 | 180-435 | 0.0094 | 5600/3000 |
N3 | 3000 | 1.57-4.35 | 390-535 | 0.007 | 5600/3000 |
N4.5 | 4500 | 1.57-8.89 | 390-535 | 0.007 | 3000 |
N6 | 6000 | 1.57-8.89 | 390-535 | 0.007 | 3000 |
N7.5 | 7500 | 1.57-8.89 | 390-535 | 0.007 | 3000 |
N9 | 9000 | 1.57-8.89 | 390-535 | 0.007 | 3000 |
N12 | 12000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
N15 | 15000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
N18 | 18000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
N20 | 20000 | 2.3-8.89 | 390-535 | 0.006 | 3000 |
N25 | 25000 | 2.3-8.89 | 390-535 | 0.0047 | 3000 |
N30 | 30000 | 2.3-8.89 | 390-535 | 0.0047 | 3000 |
N40 | 40000 | 3.5-8.89 | 430-535 | 0.0047 | 3000 |
N50 | 50000 | 3.5-8.89 | 430-535 | 0.0047 | 3000 |
Pre-design Reference | |||||
Back Pressure Steam Turbine Generator Specification | |||||
Model | Rated power(KW) | Inlet Steam Parameter | Exhaust Pressure MPa(a) | Rated Speed (r/min) | |
Pressure(MPa) | Temperature°C | ||||
B1-3 | 1000-3000 | 0.9-4.9 | 260-435 | 0.1-1.6 | 3000 |
B3 | 3000 | 1.2-8.89 | 350-535 | 0.29-2.0 | 5600/3000 |
B4.5 | 4500 | 1.2-8.89 | 350-535 | 0.29-2.0 | 3000 |
B6 | 6000 | 1.2-8.89 | 350-535 | 0.29-2.0 | 3000 |
B7.5 | 7500 | 1.2-8.89 | 350-535 | 0.29-2.0 | 3000 |
B9 | 9000 | 1.2-8.89 | 350-535 | 0.29-4.0 | 3000 |
B12 | 12000 | 1.2-8.89 | 350-535 | 0.29-4.0 | 3000 |
B15 | 15000 | 1.2-8.89 | 350-535 | 0.29-4.0 | 3000 |
B18 | 18000 | 1.2-8.89 | 350-535 | 0.29-4.0 | 3000 |
B20 | 20000 | 2.3-8.89 | 390-535 | 0.29-4.0 | 3000 |
B25 | 25000 | 2.3-8.89 | 390-535 | 0.29-4.0 | 3000 |
B30 | 30000 | 2.3-8.89 | 390-535 | 0.29-4.0 | 3000 |
B40 | 40000 | 3.5-8.89 | 430-535 | 0.29-4.0 | 3000 |
B50 | 50000 | 3.5-8.89 | 430-535 | 0.29-4.0 | 3000 |